What was found
LH FR16 UPPER DOUBLE JOGGLE HOLE #6 HAS CRACK INDICATION IN FRAM E LAYER. .328 AND INSTALLED 1ST OVERSIZED FASTENER IAW SRM FROM RPR EMBODIMENT WITH SUBSEQUANT INSP AT 6,800 FC IAW SRI 53-11-12-300-12. THIS IS A CAT B RPR REQUIRES INSP AT 6,800 FC 53-11-12-205-008 TBL 1. REAMED HOLE #6 IN LH FR16 UPPER DBL JOGGLE FROM .312 TO .326 ACCOMPLISHED HFEC WITH NO DEFECTS NOTED. FINAL REAMED HOLE 6 TO CARRY APPROVED PER SRI 53-11-12-205-008. INSPECTION THRESHOLD TOMC-APPROVAL FROM SC1ELBYC COMMENT FROM TIME OF REPAIR EMBODIMENT IS 6,800 FLIGHT CYCLES. SUBSEQUENT INSPECTIONS AT INTERVALS OF 6,800 FLIGHT CYCLES UNTIL 60,000 FLIGHT CYCLES. THE CURRENT PTC IS 34,270.