Service difficulty report · Power Supply · Airbus A319132

Difficulty date
January 3, 2025
Submitted
January 6, 2025
Operation
Air carrier
Aircraft
N892UA
Make and model
Airbus A319132
Aircraft serial
2940
Aircraft time
49,004 hours, 28,673 cycles
Part
Power Supply
Part number
32145410
Part serial
008208
Condition
Faulted
Location
Zone 200
Part time
748,983 hours, 728,664 cycles
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT EMERGENCY POWER SUPPLY BATTERY 12WL REQUIRES REPLACEMENT. REPLACED POWER SUPPLY AND BATTERY REF AMM 33-51-38. TESTED NORMAL.PARTS USED: 18-3351-3-0001,QTY :1 31-3350-9-9001,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1835569 SN OFF 8208 IPC REFERENCE # 33-51-04-03 POWER SUPPLY, P OFF 31-3350-9-9001 8208 ON 31-3350-9-9001 8235