MAIN CABIN AFT WET AREA FLOOR SUPPORT ANGLE STA 986.5+6" RBL 31"-36" SCRATCH MARKED. (REF AAR N/R 9937214) INSTALLED NEW SUPPORT ANGLE AT AFT WET AREA STA 986.5+6 RBL 31"-36" REF SRM 51-40-02-0G-0 AND DWG 147A5700.