What was found
CRACK OF 0.350" APROX LENGTH COMING OUT FROM FASTENER AT LH SIDE FR35 FWD SURFACE TO THE PRESSURE BULKHEAD BELOW STR 30 LH. ACCOMPLISH A PERMANENT REPAIR AT LH FR35 STGR30LH FRAME WEB LATEST REVISION OF ECRA 5330-07424 ON OR BEFORE 11-AUG-25 PER HOLES #A AND #B AND FRAME FLANGE HOLE #2 PER PART 3 OF THE PART 1 STEP 2 OF ECRA 5330-07424. REF. HAECO LCQ NR 292651 FOR WORK PERFORMED. ACCOMPLISHED INTERIM REPAIR IAW ECRA 5330-07424 PART 1 STEP 1. DIP REQUIRED WORK ACCOMPLISHED ABOUT EC/RA 5330-07424. NO ISSUES. OK TO CARRY CRACK OF 0.350" APROX LENGTH COMING OUT FROM TOMC-APPROVAL FROM SC1ELBYC COMMENT FASTENER AT LH SIDE FR35 FWD SURFACE TO ACCOMPLISH A PERMANENT REPAIR AT LH FR35 STGR30LH FRAME WEB HOLES #A AND #B AND FRAME FLANGE HOLE #2 PER PART 3 OF THE LATEST REVISION OF ECRA 5330-07424 ON OR BEFORE 11-AUG-25.IN REF TO ECRA 5330-07424 QC QC REVIEWED. INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS REVIEW.