What was found
OPERATIONAL CHECK OF CABIN EMERGENCY LIGHTS {A3NB-33-3-6012} - FAILED TEST. EPSU BATTERY AFT L MESSAGE CAME UP. REPLACED EMER LIGHT BATTERY AT DOOR 2L. EMER LIGHT TEST AT PTP PANEL PASSED.PARTS USED: 18-3351-3-0001,QTY :1
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OPERATIONAL CHECK OF CABIN EMERGENCY LIGHTS {A3NB-33-3-6012} - FAILED TEST. EPSU BATTERY AFT L MESSAGE CAME UP. REPLACED EMER LIGHT BATTERY AT DOOR 2L. EMER LIGHT TEST AT PTP PANEL PASSED.PARTS USED: 18-3351-3-0001,QTY :1