What was found
STAB TRIM FAIL AFTER TAKEOFF. REMOVED STAB TRIM MOTOR REF AMM 27-41-71-000-801 REPLACED STAB TRIM MOTOR REF AMM 27-41-71, ACP STAB MOTOR TEST REF AMM TASK 27-41-71-700-801, TO STEP C-8-A, CHECKS GOOD. NEEDS STAB TRIM LIMIT SWITCH TEST AND STAB TRIM MOTOR AUTO PILOT TEST PER STEP D TO BE ACCOMPLISHED PARTS USED: 29-2741-9-0013,QTY MOTOR, STAB, HO OFF 29-2741-9-0011 6529 ON 29-2741-9-0013 7104 :1 1445224,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1445224 SN OFF 6529 NEEDS TO BE INSPECTED FOR PROPER INSTALL INSPECTED INSTALLATION PER AMM 27-41-71-400-801 ACPD STAB TRIM LIMIT SWITCH TEST AND STAB TRIM MOTOR AUTO PILOT TEST PER AMM TASK 22-11-81-710-801 AND AMM 27-41-00-700-805 ALL TESTS PASSED. PERFORMED LAND VERIFY TEST REF AMM TASK 22-11-00-700-801. ALL TESTS PASS, ACFT RETAINS FULL AUTOLAND ADD EMP:U348453 STATUS. INSPECTED STAB MOTOR AND JACKSCREW AREA NO DEBRIS FOUND AREA LOOKS CLEAN AND JACKSCREW PANEL IS CLOSED.