What was found
AFT ENTRY DOOR LIGHT ILLUMINATED AT ABOUT 90 KNOTS UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. MAC METER INITIATED FOR WITH VENDOR ID MAC RELATED WORK ORDER 000000003130133. DEBRIEFED THE CREW AND FOUND THE DOOR HANDLE DID NOT MOVE DURING THE LIGHT COMING ON. CYCLED DOOR HANDLE AND FOUND LIGHT DOES NOT ALWAYS EXTINGUISH WHEN DOOR IS CLOSED. PLACING AFT ENTRY DOOR L2 DOOR WARNING INDICATION ON DEFERRAL IAW MEL 5203B DOOR INDICATION NOT DEACTIVATED. DEBRIEFED THE CREW AND FOUND THE DOOR HANDLE DID NOT MOVE DURING THE LIGHT COMING ON. CYCLED DOOR HANDLE AND FOUND LIGHT DOES NOT ALWAYS EXTINGUISH WHEN DOOR IS CLOSED. PLACING AFT ENTRY DOOR L2 DOOR WARNING INDICATION ON DEFERRAL IAW MEL 5203B DOOR INDICATION NOT DEACTIVATED. DEFERRED DIRECTLY BY TOMC CHECKED AFT ENTRY DOOR ADJUSTMENTS ,OPS CHECKED DOOR HANDLE PER AMM 52-13-00-820-801 WITHIN HANDLE LIMITS. CYCLED DOOR SEVERAL TIMES. LIGHTS COME ON AND GOES OFF HAS IT SHOULD PER ENTRY DOOR SENSOR (S200) TEST IAW AMM 52-71-11-710-801. ACCOMPLISHED TEST FOR AFT ENTRY DOOR SENSOR (S200) AT PSEU . SENSOR IS AT OPTIMUM GAP IAW WITH AMM 52-71-11-820-801. REMOVED PLACARD.