What was found
EMERGENCY AREA LIGHT SEATS 21DEF INOP LED LIGHT BELOW EXIT SIGN AT ROW 21 DEF IS OUT. SEE PHOTO. LIGHT INOP. APPROVED. NOT AN EMERGENCY LIGHT. PLACED ON 3321A. *DM* ASSIST: DRWG 2520DD15047 SHOWS 21F AS AFT OWE @ APPROX STA 628. FROM IPC 33-51-51-74D & WDM 33-21-12-3: ORDERED 14" TYP-B AFT OWE LT M2338 I.310/60-3321-3-0008. PRECAUTIONARILY ADDED TY-F LT I.315/60-3321-3-0009, TY-C LT M2830/29-3321-3-0125, AND TY-E LT M2800/60-3322-3-0005 IN-CASE OTHER STYLE REQD. ADJ M&L TO 6 TO ALLOW FOR EXIT LINING REMOVAL, REF AMM 33-21-00-960-802 REMOVED AND REPLACED EMERGENCY AREA LIGHT.