What was found
STATION 663 BULKHEAD VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT APPROX. LBL 9.0. SUPPORT TASK NSA EMX N/R 00102. ESFR ENTERED REPAID STATION 663 BULKHEAD VAPOR BARRIER UPPER ATTACH ANGLE AT LBL 9.0 IAW B737-900 SRM 57-10-10-2R-5 AND ACCOMPLISHED FUEL LEAK CHECK IAW B737-900 AMM 28-11-00 LEAK CHECK GOOD FOR WORK ACCOMPLISHED. REPAIRED STATION 663 BULKHEAD VAPOR BARRIER UPPER ATTACH ANGLE AT LBL 9.0 IAW B737-900 SRM 57-10-10-2R-5 AND ACCOMPLISHED FUEL LEAK CHECK IAW B737-900 AMM 28-11-00 LEAK CHECK GOOD.