As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R/H FR16 DOUBLE JOGGLE HOLE "C" HAS A CRACK INDICATION AT 9 O'CL OCK IN THE FRAME LAYER. REPAIRED HOLE C R/H FRAME 16 DOUBLE JOGGLE WITH BUSHING AND WASH ER IAW SRM 53-11-12-300-012. FINAL HOLE SIZE REAMED WITH BUSING INSTALLED IS .2175. HFEC ACCOMPLISHED WITH NO FINDINGS.