What was found
DOUBLE JOGGLE AT RT FR 20 HOLE #6 HAS CRACK INDICATION IN FRAME LAYER, 3 DIRECTION, 100% S.H. REPAIRED HOLE #6 AT RH FR20 DOUBLE JOGGLE WITH BUSHING AND RPR WASHER IAW SRM 53-11-12-300-012. FINAL REAM .2800 THIS IS A CAT B. COMPLETED DOUBLE JOGGLE AT RH FR 20 HOLE #6 HAS CRACK INDICATION IN FRAME LAYER, 3 DIRECTION, 100% S.H. REPAIRED HOLE #6 AT RH FR20 DOUBLE JOGGLE WITH BUSHING AND RPR WASHER IAW SRM 53-11-12-300-012. FINAL REAM .2800 THIS IS A CAT B.