What was found
COCKPIT TEMP TOO HOT AND TEMPO UNCOTROLLED AFTER QRH TEMP EVENTU ALY BEGAN TO COME DOWN PER PILOTS-ON THE TAKEOFF ROLL COCKIT VENT OUTLETS POURED OUT AIR THAT WAS EXTREMELY HOT. IN THE CLIMB TEMPS CONTINUED LET OUT HOT AIR. EVENTUALLY AFTER RUNNING QRH TEMPS STARTED TO RETURNTO NORMALL, WITH CONTROLLERS IN THESBY-C POSITION. FOLLOWED FIM 21-60 FAULT TREE 809 AND COCKPIT VALVE NOT FULLY RESPONDING, SUSPECT VALVE NEEDS REPLACED PER FIM. REMOVED AND REPLACED FLT DECK TRIM AIR VALVE IAW 21-61-07-404-031 UP TO BUT NOT INCLUDING STEP F (12) OPERATIO AND LEAK CHECKS , PERFORMED CLEANING OF FLT DECK TEMP CONTROL SENSOR PER SERVICE TIP 21-61-00/201. COMPLETED INSTALLATION OF FLIGHT DECK TRIM AIR MODULATING VALVE REF AMM 21-61-07. OPS CHECK LEAK CHECK GOOD. REF FIM 21-60 FAULT TREE 809. BITE TEST GOOD. NO FAULT NOTED.