Service difficulty report · Transmitter · Airbus A319131

Difficulty date
May 22, 2025
Submitted
May 27, 2025
Operation
Air carrier
Aircraft
N812UA
Make and model
Airbus A319131
Aircraft serial
850
Aircraft time
79,938 hours, 34,789 cycles
Part
Transmitter
Part number
C90ST0003
Part serial
6044
Condition
Faulted
Location
Hyd System
Part time
8,984 hours, 4,664 cycles
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTS GREEN HYDRAULIC LEVEL DROPPED QUICKLY IN FLIGHT. WHEN RETURNING TO GROUND AND PUTTING A LOAD ON SYSTEM GREEN HYDRAULIC FLUID LEVEL WENT BACK UP TO SATISFACTORY. HYDRAULIC PRESSURE REMAINED CONSTANT. PERFORM DETAILED WALK AROUND DID NOT FIND ANY LEAKS. LIKELY AN INDICATION ISSUE. NEED TO CHANGE HYDRAULIC QUANTITY INDICATOR AS PRECAUTIONARY. THE FLUID LEVEL INDICATED WAS NOT LOW ENOUGH TO TRIGGER THE LOW LEVEL SWITCH AND WAS IN OPERATIONAL RANGE OF THE QUANTITY INDICATOR. REMOVED AND REPLACED GREEN RESERVOIR QUANTITY INDICATOR IAW AMM 29-11-41-400-002-A. PERFORMED THE LOW LEVEL WARNING TEST IAW AMM 29-31-00-710-001-A. LEAK CHECK GOOD. PERFORMED 5 MINUTE ENGINE RUN WITH ENGINE PUMP ON AND FLIGHT CONTROLS MOVING. NO FAULTS NOTED. ALSO VERIFIED CORRECT ACCUMULATOR PRESSURE. AC OK FOR SERVICE.