What was found
REQUESTING ENGINEERING SUPPORT FOR EA5310-08195 REVISION B OP 003 LH SIDE NUMBER 3 WINDOW FRAME POST - PERMANENT REPAIR, FASTENER HOLE NUMBER 3 (BOTTOM TO TOP) HAS A CRACK SIGNAL NOTED AT 9 O?CLOCK POSITION. FASTENER HOLE CURRENTLY IS 0.297 INCHES OF DIAMETER, ACCORDING TO STEP B (26), ENGINEERING SUPPORT IS REQUIRED FOR REPAIR INSTRUCTIONS (REF. AAR NR 1000032778). ESFR INFORMATION UPDATED. REPAIRED FASTNER HOLE NUMBER 3 (BOTTOM TO TOP) WITH CRACK SIGNAL NOTED AT 9 O'CLOCK POSITION AT L/H SIDE NUMBER 3 WINDOW FRAME P OST IAW EC/RA 5310-08591 STEPS 1-34