What was found
CONTINUED REMOVING LEFT AFT EMERGENCY EXIT DOOR FOR R&E ACCESS. REF AMM TASK 52-22-00-000-801 FROM STEP (2) F TO STEP (2) L. DOOR REMOVED, HARDWARE BAGGED AND PLACED ON DOOR FRAME. DOOR REMOVED. INSTALLED AFT L/H EXIT DOOR INTO FUSELAGE AND INSTALLED, TORQUED, SAFTIED FWD AND AFT DOOR HINGE BOLTS ONLY. SNUBBER AND COUNTERBALANCE ACTUATOR BOLTS TEMP INSTALLED, REF LOG #5074328. VERIFIED TWO EACH HINGE BOLTS REPLACED. ACP INTERFACE INSPECTION OF HINGE ATTACH POINTS. REPLACED 3 DAMAGED BOLTS FOR COUNTERBALANCE ACTUATORS AND SNUBBER IN REF. AMM 52-22-00. OPS CHECKED OK. VERIFIED THE SAFETY AND SECURITY INSTALLLSTION OF L/H AFT OW EXIT DOOR.