What was found
BODY BELOW AFT CARGO COMPARTMENT FLOOR (INTERNAL) INSPECTION: IT WAS FOUND SIGNS OF CORROSION BELOW FLOORBEAM AT BS 1131, S-34R IT WAS CREATED ESFR NECESSARY QC REVIEW AND APPROVAL. PERFORMED INSPECTION AND APPROVED THE REPAIR AS PER EC/RA #5360-01963, PERFORMED PERMANENT FLOORBEAM REPAIR AT BS 1131, S-34R AS PER EC/RA #5360-01963. ITEM OK TO SERVICE.