Service difficulty report · Power Supply · Boeing 737824

Difficulty date
June 15, 2025
Submitted
June 19, 2025
Operation
Air carrier
Aircraft
N77539
Make and model
Boeing 737824
Aircraft serial
63642
Aircraft time
24,802 hours, 9,159 cycles
Part
Power Supply
Part number
D71702001
Condition
Discharged
Location
Zone 200
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EMERGENCY LIGHTING SYSTEM FUNCTIONAL CHECK (INTERIOR AND EXTERIOR) {MULT-33-3-0004} - M1673 FAILED FUNCTIONAL CHECK. REPLACED BATTERY PACK IN M1673 POWER SUPPLY TWICE, IAW AMM 33-51-06-960-805, UP TO AND INCLUDING STEP 4.E.(6)(B). TEST BUTTON ON POWER SUPPLY DOES NOT WORK. EMERGENCY LIGHTS FOR THIS POWER SUPPLY COME ON WHEN ATTENDANT PANEL SWITCH IS USED. NEED NEW CHARGER ASSY.PARTS USED: 99-3351-3-0015, QTY :2 REPLACED EMERGENCY LIGHT POWER SUPPLY M1673. 33-51-06-960-806. OP. CKS GOOD. PARTS USED: 53-3351-3-0013,QTY :1