What was found
GREEN RSVR PRESS LOLOOS OF GREEN SYSTEM. HYDRALIC LEAK FOUND ON HYDRALIC LINE FROM T/R SHUTOFF VALVE TO T UNION IN PYLON IPC 29-11-06-02L ITEM 260 SDR FLAGGED CONFIRMED HYDRALIC LEAK ON HYDRALIC LINE FROM T/R SHUTOFF VALVE TO T UNION IN PYLON IPC 29-11-06-02L ITEM 260. BOLT (130) FOUND DAMAGED AND CAUSED LINE TO BECOME DAMAGED IN MULTIPLE AREAS. REMOVED HYD LINE. NEW LINE READY FOR INSTALL. RAR ENG #1 PIPE PN D2901010201200 AND BOLT PN NAS6704U12 IAW AMM 29-11-49 AND IPC 29-11-06-02L. LEAK AND OPS CHK REQUIRED. OPS AND LEAKED CHKED ENG #1 PIPE PN.D2901010201200 AND HYD EDP IAW AMM 29-11-51 AND 29-11-49. NO LEAKS AND NO FAULTS FOUND DEBRI IN ENG #1 HYD EDP CASE DRAIN FILTER. PERFORMED ALTERNATE PROCEDURES OF FLUSHING OF THE GREEN HYD SYS OF THE EDP IAW AMM 12-36-29-170-001-A UP TO STEP 4.D.(3)(C). ENG RUN STILL REQUIRED. ACCOMPLISHED #1 ENG RUN. CHECKED DELTA P OF HP AND CASE DRAIN FILTERS DELTA P NOT EXTENDED ALSO COMPLETED FLUID SAMPLE REF AMM 12-36-29-170-001-A FROM STEP D (4) TO COMPLETION.