What was found
AFT WET AREA, DURING REPAIR PROCESS OF FLOOR SUPPORT 986.5, FOUND C ORROSION ON INNER CHORD STA 887 TO 1016 LBL 45 REQUIRE REPLACE ( REF AAR NR 1000038955) ESFR & SDR DETAILS UPDATED. REMOVED AND REPLACED NEW INNER CHORD ON AFT WET AREA BTW STA 100 6 TO 887 LBL 45, IAW B737-800, DWG 147A8540, SRM 51-40-05-0G-0, 51-40-08-0G-0, 51-40-02-0G-0.