What was found
CREW REPORTS RT ENG EGT EXCEEDED DURI NG CLIMB. AHM SHOW ENG R EGT RED MM MSG 77-62122, AHM DID NOT TR IGGER EGT EXCEEDANCE REPORT FOR RT ENG IAW AMM 31-61-00-8 00-804 (201), NOTE DOWN EGT PEAK & DURATION FROM RT ENG EXCD. EXCEEDANCE OF 20.4 SECONDS AT 629.5 CELCIUS OVER LIMIT BUT WITHIN AREA "A" OF FIGURE 603 REF AMM TASK 72-00-00-290-818-N01. ENG OVERTEMP INSPECT REQ'D. ENG EGT OVERLIMIT FOR MORE THAN 5 SECS. ACP'D EGT OVERTEMPERATURE INSPECTION IAW 72-00-00-290-818-N01. GVI GOOD. INSPECTED IGNITION PLUG LEADS IAW AMM 74-21-01-200-801-N00. NO DAMAGES NOTED. BOROSCOPE INSPECTION. NO DEFECTS NOTED. AP-8 PLUG AT 1:30 O'CLOCK, AP-10, AND AP-11 HAVE BEEN REMOVED FOR BOROSCOPE & REINSTALLED IAW AMM SUBTASK 72-00-00-290-050-N01. CHANGING INSPECTION TO IDT FOR BORO PLUG REQUIREMENT REF GMM 09-10-05. ACPD BOROSCOPE IDPI NOT EXTENDED ON FUEL SERVO HEATER FILTER. REF TEST NO. 6 - EEC IDLE CHECK REFERENCE: TASK 71-00-00-730-801-N00.