What was found
30ABC LOWER AISLE EMERGENCY LIGHT OUT 30ABC FLOOR PROXIMITY LIGHT ASSY REM AND REPL. REF AMM 33-51-11-960-802. LIGHT STILL WONT TURN ON. FURTHER TS REQUIRED. MEL 3319E. CW MEL REQUIREMENTS FLOOR PROXIMITY LIGHT INDICATED ON LOWER AISLE 30ABC WAS FOUND UPON TROUBLSHOOTING THAT THE HARNESS WAS DISCONNECTED. NO ENERGY WAS CONNECTED TO THE LIGHT. RECONNECTED FEMALE TO MALE CONNECTION AND OPS CHECK ILLUMINATION. EMERGENCY PROXIMITY LIGHT WORKS AND NO NECECESSARY FURTHER ACTIONS WERE REQUIRED. REF. AMM 33-51-11-960-802.