What was found
FOUND MED 4R EPAS GREEN LIGHT NOT BLINKING WHEN IN ARMED POSITION. REF. AMM 52-11-00. RESETTED CB AT P11 H 18. 4L EPAS GREEN FLASHING AND 4R NOT FLASHING. REMOVED AND REPLACED EMERGENCY POWER ASSIST SYSTEM (EPAS) BATTERY PACK REFERENCE: TASK 52-11-20-400-813. OPS CHK GOOD. REQUIRES INSPECTION BUY BACK FOR INSTALLATION, REMOVAL OF SLIDE SAFETY PINS, AND OPENING AND CLOSING OPS CHK REFERENCE: TASK 25-66-01-820-801. OK FOR SERVICE. ACP'D RII INSPECTION, VERIFIED DR.4R ESCAPE SLIDE SAFETY PINS REMOVED AND STOWED, SLIDE BUSTLE INSTALLED, OP-CHKD GOOD.