What was found
DURING OPEN HOLE HFEC INSPECTION OF NR 2731310 WAS FOUND CRACK HOLE INDICATION AT STGR 39LH AND STA 1395 PERFORMED INSPECTION. PERFORMED PERMANENT REPAIR AT STRINGER S-39L BTW STA1395 AND STA1417 AS PER ECRA 5360-01975. PERMANENT REPAIR AT STRINGER S-39L BTW STA1395 AND STA1417 WAS ACCOMPLISHED AS PER ECRA 5360-01975.