What was found
ON TAKE OFF MASTER CAUTION DOOR ILLUMINATED THEN WENT OUT. UNABLE TO DETERMINE WHICH DOOR TS SYSTEM REF FIM 52-10 TASK 801. PSEU LOGGED INTERMITTANT L1 DOOR FAULT, 52-71001, FUNCTION TESTED SYSTEM, REF SAME FIM, SYSTEM TESTS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON TAKE OFF MASTER CAUTION DOOR ILLUMINATED THEN WENT OUT. UNABLE TO DETERMINE WHICH DOOR TS SYSTEM REF FIM 52-10 TASK 801. PSEU LOGGED INTERMITTANT L1 DOOR FAULT, 52-71001, FUNCTION TESTED SYSTEM, REF SAME FIM, SYSTEM TESTS NORMAL.