SHEAR WEB @ FR 11 ON F/O SIDE UNDER FLOOR CRACKED. REMOVED AND REPLACED SHEAR WEB, FR 11, F/O SIDE UNDER FLOOR IAW SRM 51-42-11 AND SURFACE PROTECTION IAW SRM 51-23-11 AND 51-21-00.