What was found
CORROSION AROUND G4 GALLEY FITTING AT FLOOR STRUTURE STA986.5+8" RBL 39. REMOVED AND INSTALLED NEW MACHINED WEB FROM STA 986 TO STA 1016 RBL 39" REF B 737-900ER SRM 51-40-02-0G-0 AND DWG # 147A5701.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AROUND G4 GALLEY FITTING AT FLOOR STRUTURE STA986.5+8" RBL 39. REMOVED AND INSTALLED NEW MACHINED WEB FROM STA 986 TO STA 1016 RBL 39" REF B 737-900ER SRM 51-40-02-0G-0 AND DWG # 147A5701.