What was found
BREAKAWAY ON PUSHBACK TUG DRIVER MENTIONED SCRAPE ON PAINT. RE-EVALUATED SCRAPE FOUND AS FOLLOWS, SCRAPE MEASURES 17.5 INCH L BY 3 INCH W, TOTAL AREA, DEPTH OF SCRAPE IN TO METAL IS .040 DEEP. APPROX 4 INCHES OUT BOARD FROM FORWARD NLG DOOR. SCRAPE HAS A DENT AT AFT SECTION THAT MEASURES 6 INCH L (FOR & AFT) & 3 INCH W (INBD & OTBD) & .100 D. SCRAPE RUNS THROUGH 8 FASTENERS. AREA IS OUT OF LIMITS IAW SRM 53-11-11. UPON FURTHER INSPECTION OF DAMAGED AREA & REEVALUATION OF SCRATCHES ACTUAL DAMAGE SHOULD READ 2 SCRATCHES. FIRST 15.5 L WITH DEEPEST MATERIAL LOSS BEING .011 DEEP, SCRATCH IS LOCATED IN ZONE 1 & ZONE 2 OF SRM 53-11-11-283-017. SECOND SCRATCH IS 3.5 LONG, WITH DEEPEST MATERIAL LOSS OF .024 DEEP. THE DENT IS ISOLATED BETWEEN FR 10 & 11, STRINGER 607, & RT LOWER STRINGER IN POCKET AREA. DENT MEASURES 6 LONG. 4 WIDE INCH. ACOMPLISHED STEPS 1 & 2 OF AVO 15164. 16 FASTENERS REMOVED. ACCOMPLISHED AVO 15164 REV. C ITEMS 2, 3, 5, & 7. AVO 015164 STEP 9. COMPLETED ULTRASOUND GRID MAPPING & NTM 51-10-04. A MAJOR REPAIR AND IT IS AN RII ITEM.