What was found
TEST SHOWS EPSU INT LOAD EMER R MSG---PROCEDURE - PERFORMED VISUAL CHECK OF THE CABIN EMERGENCY-LIGHT SYSTEM REF AMM 33-51-00-710-009-A. FOUND OVERWING EXIT-FWD AISLE LIGHT INTERMITTENT. LIGHT IS NORMALLY OFF BUT ILLUMINATES AND STAYS ON AFTER LIGHT PRESSURE IS APPLIED TO LENS. THIS NORMALLY MUST BE REPEATED AFTER EVERY CYCLE OF EITHER EMERGENCY LIGHT SWITCH. SUSPECT BAD LIGHT FIXTURE. FOUND MID CABIN FWD EXIT SIGN 51WL LED PANNEL NOT SECURED IN ASSEMBLY. RESECURED LED PANEL, LIGHT WORKS FINE EVEN WHEN TAPPING ON IT. PERFORMED EPSU BITE CHECK REF AMM 33-51-00-710-001-A. OPS TEST GOOD, NO FAULTS NOTED