What was found
CEILING SUPPORT AT L/H FR 1640 HAS A CRACK AT SCREW HOLE. REMOVED, FABRICATED AND INSTALLED CEILING SUPPORT CHANNEL IAW SRM 51-40-02 AND PRODUCTION DWG 411N3141.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CEILING SUPPORT AT L/H FR 1640 HAS A CRACK AT SCREW HOLE. REMOVED, FABRICATED AND INSTALLED CEILING SUPPORT CHANNEL IAW SRM 51-40-02 AND PRODUCTION DWG 411N3141.