What was found
LEFT LEADING EDGE SLAT 7 & 8 HAS DAMAGE ON UPPER INBOARD SIDE OF THE SLAT. THERE ARE 9 DAMAGED RIVETS AND THE HOLE MEASURES 4.5 INCHES IN WIDTH AND 2 IN LENGTH. PERFORMED TASK IN AMM REF 27-81-10 UP TO (E) (5) (A). REMOVED FASTENERS AND CUT OUT DAMAGED SECTION OF UPPER SLAT SKIN IAW SRM 57-43-01-2R-6 REPAIR 6 STEPS 1. THROUGH 4. D. AND AVO15346. COMPLETED HFEC OF REPAIR CUTOUT PER AVO 15346 AND SRM 51-00-04-0G-0 & SRM 57-43-01-2R-6 NO DEFECTS FOUND. FABRICATED, DRILLED, COUNTERSUNK & DEBURRED -1 PLATE, -2 DOUBLER AND -3 POCKET SHIM REF. SRM 57-43-01-2R-6 REPAIR 6 STEPS 4. F. THROUGH 4.J. ALODINE & PRIME IAW SRM 57-43COMPLIED WITH GMM 9-25-05 & AVO 15346. REPAIR COMPLETE IAW SRM 57-43-01-2R-6 REPAIR 6.