What was found
EMER EXIT LIGHT AT 20C IS HANGING OFF OF THE SEAT REPLACED END BAY BUMPER AND SECURED EMERGENCY LIGHT AT SEAT 20C REF CMM 25-21-58. OPS CHECK OF EMERGENCY LIGHTS GOOD IAW AMM 33-51-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMER EXIT LIGHT AT 20C IS HANGING OFF OF THE SEAT REPLACED END BAY BUMPER AND SECURED EMERGENCY LIGHT AT SEAT 20C REF CMM 25-21-58. OPS CHECK OF EMERGENCY LIGHTS GOOD IAW AMM 33-51-00.