What was found
FRAME 35, S30R HOLE #1, #3, #9 DAMAGED.ACCOMPLISHED INTERIM REPAIR PER ECRA 5311-02126 REV C. WITH NO DEVIATIONS. ACCOMPLISH INSPECTION REQUIREMENTS AT RH FR35 STGR30RH ANGLE FITTING AND LH/RH FR35 STGR30 HOLES #1, #3-#9 PER PART 2B OF THE LATEST REVISION OF ECRA 5330-07562. INTERIM REPAIR TO FR35 STGR LT HOLE #3 AND RT HOLE #2 PER ECRAS 5311-02126 AND 5330-07562. MUST ACCOMPLISH INSPECTION REQUIREMENTS AT RT FR 35 STGR30RH ANGLE FITTING AND LT & RT FR 35 S30 HOLES #1, #3-#9 PER PART 2B OF THE LATEST REVISION OF ECRA 5330-07562.