What was found
MAIN CABIN R1 DOOR CUT OUT SILL SCUFF PLATE ATTACH FLANGE IN THE CREASE BEAM IS CORRODED UPPER SURFACE IN MULTIPLE SPOTS. REMOVED AND REPLACED -5 ANGLE AT MAIN CABIN R1 DOOR IAW BAC DWG 141T5310 REV:- SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN R1 DOOR CUT OUT SILL SCUFF PLATE ATTACH FLANGE IN THE CREASE BEAM IS CORRODED UPPER SURFACE IN MULTIPLE SPOTS. REMOVED AND REPLACED -5 ANGLE AT MAIN CABIN R1 DOOR IAW BAC DWG 141T5310 REV:- SRM 51-40-02.