What was found
DURING CLIMBOUT HAD INDICATION OF POSS FUEL LEAK SHOWED 8K LOSS REQUEST TO MEL. INSPECTED AIRCRAFT UPON ARRIVAL. NO FUEL LEAKS NOTED. RIGHT FUEL QTY INDICATION INOP PROBE #24 AT FAULT PLACARD INSTALLED. REPLACED PROBE #24 REF AMM 28-41-02-400-801 CHECKED SAFETY AND SECURITY OF #24 PROBE INSTALLATION, CLEARED TO CLOSE TANK PLATE. VERIFIED INSTALLATION OF #24 FUEL PROBE AND CLEARANCE TO INSTALL WING PLATE 642AB. OPS TESTED FQIS REF MM 28-41-00-710-801.NO FAULTS.REMOVED STICKER.