Service difficulty report · Warning Light · Airbus A320232
FAA SDR system
- Difficulty date
- September 2, 2025
- Submitted
- September 5, 2025
- Operation
- Air carrier
- Make and model
- Airbus A320232
- Aircraft serial
- 2680
- Aircraft time
- 54,125 hours, 26,503 cycles
- Part
- Warning Light
- Condition
- False Activation
- Location
- Start Valve
- Stage of operation
- TX
- How discovered
- O
- Nature of condition
- N
- Precautionary procedure
- O
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ECAM ENG 1 START VALVE FAULT REQUESTING DEFFERAL 8011M ENG 1 START VALVE INDICATION ERRONIOUS. START VALVE VERIFIED CLOSED AMM 80-11-00-040-042-A. COMPLIED WITH DDP. PERFORMED OPS TEST OF ENG 1 START VALVE IAW TSM 80-00-00-810-801-B. NO FAULTS FOUND, OPS CHECKED GOOD.
More about the Airbus A320-232