Service difficulty report · Warning Light · Airbus A320232

Difficulty date
September 2, 2025
Submitted
September 5, 2025
Operation
Air carrier
Aircraft
N4901U
Make and model
Airbus A320232
Aircraft serial
2680
Aircraft time
54,125 hours, 26,503 cycles
Part
Warning Light
Condition
False Activation
Location
Start Valve
Stage of operation
TX
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ECAM ENG 1 START VALVE FAULT REQUESTING DEFFERAL 8011M ENG 1 START VALVE INDICATION ERRONIOUS. START VALVE VERIFIED CLOSED AMM 80-11-00-040-042-A. COMPLIED WITH DDP. PERFORMED OPS TEST OF ENG 1 START VALVE IAW TSM 80-00-00-810-801-B. NO FAULTS FOUND, OPS CHECKED GOOD.