As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXFOLIATION CORROSION FOUND ON FWD WET AREA FLOOR SUPPORT AT BS 294.5 +6 INCHES LBL 11. EVALUATED DAMAGE: ORIGINAL MATERIAL 0.090", MATERIAL LOST 0.028", MATERIAL REMAINING 0.062", FOUND OUT OF LIMITS PER SRM 53-10-51-1A-1 FIG. 105 DET. F. REMOVED AND INSTALLED NEW FLOOR SUPPORT AT MAIN CABIN WET AREA LBL 11 BETWEEN STA 294.5 AND STA 312 PER SRM 51-40-02-0G-0 AND DWG 141A5600.