What was found
SEVERAL SPOTS WITH EVIDENCE OF SURFACE CORROSION AT FWD WET AREA FLOORBEAM TOP SURFACE STA 328 RBL 38 TO RBL 58. REMOVED DAMAGED TEE AND ACCOMPLISHED NEW TEE FABRICATION AT WET AREA FLOORBEAM IAW SRM 51-40-02-0G-0,SRM 53-10-51-2R-7 AND EC-RA 5321-01706.