What was found
CORROSION FWD WET AREA AT FLOORBEAM STA 344 LBL 57. REMOVED CORROSION AT FWD WET AREA FLOORBEAM STA 344 LBL 57" IAW SRM 51-10-02-0G-0-.MEASURED THE AREA,ORIGINAL MATERIAL 0.175, MATERIAL LOSS 0.112", MATERIAL REMAINING 0.063", FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1 STEP 4.I GROUP 9. (2) FIGURE 105 DETAIL C. REMOVED DAMAGED AREA AND INSTALLED FLOORBEAM REPAIR AT BS 344, IAW SRM53-10-51-2R-10 REPAIR 10, DRAWINGS 140A9810, 141A8110, 141A5730, 141A5410, 141A8146, 141A5772, & 141A8147.