What was found
MAIN CABIN INTERCOSTAL BS 950 TO 967, RBL 60 CORRODED ON UPPER SURFACE, EVALUATED CORROSION ON INTERCOSTAL BELOW BS 950 TO 967, RBL 60 ORIGINAL THICKNESS .130" CORROSION DEPTH .128" REMAINING MAT .002, FOUND TO BE OUT LIMITS IAW DWG 147A5762 REV B, SRM 53-70-51. REMOVED AND INSTALLED NEW INTERCOSTAL BS 950 TO 962, RLB 60.