As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT BS 663 VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT APPROXIMATELY LBL 9.0 SUPPORT TASK NSA EMX NR 00064 SFR REPORTING ONLY REPAIRED CRACKED UPPER ATTACH ANGLE AT STATION 663 AND LBL 9.0 IAW SRM 57-10-10-2R-5 REPAIR 5 AND ACCOMPLISHED FUEL LEAK CHECK IAW AMM 28-11-00, LEAK CHECK GOOD.