What was found
EMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCH PROCEDURE, EMERGENCY LIGHT ABOVE ROW 11 DEF INOPERATIVE. REPLACED THE LAMP AISLE EMERGENCY LIGHT ABOVE SEATS 11 DEF IAW AMM 33-51-05. NO HELP. R & R AISLE EMERGENCY LIGHT HOUSING ASSEMBLY AT SEAT 11 DEF REF AMM 33-51-05. NO HELP. PERFORMED WIRING CHECKS IAW WDM 33-51-12. NO POWER FOUND AT HOUSING TERMINALS IAW WDM 33-51-13. R & R EMERGENCY LIGHT POWER SUPPLY MODULE M10919 IAW AMM 33-51-07. ALL EMERGENCY LIGHTS OPS CHECK GOOD AT THIS TIME.