What was found
MAIN CABIN FLOORBEAM AT BS 987 LBL45 CORRODED AT GIRT BAR FITTING HOLE (DOME NUT) LOCATION. REMOVED CORROSION, FOUND TO BE 100%, OUT OF LIMITS IAW SRM 53-70-51-1A-1 DETAIL C. REPAIRED AREA IAW SRM 53-70-51-2R, REPAIR 6, & SRM 51-20-01. ACCOMPLISHED DVI IAW SRM 51-10-04. ACCOMPLISHED HFEC IAW NDT PART 651-00-00 PROCEDURE 4, NO CRACK NOTED. SHOT PEEN AREA IAW SRM 20-10 -03.