What was found
TE FLAPS DISAGREE CAUTION MSG FSEU 1 LAST LEG HAD FAULT 305 - INTERMITTENT, FSEU 2 HAD FAULT 327. PERFORMED FIM 27-51 TREE 805, BITE TEST GOOD, NO EXISTING FAULTS. MSG CLEARED. CYCLED FLAPS THROUGH FULL TRAVEL MULTIPLE TIMES, FLAPS OPERATED NORMALLY.