What was found
EMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. EXIT ROW EMERGENCY LIGHT AT SEAT 3AB(AFT LIGHT) IS INOPERATIVE. PERFORMED GVI OF SEAT EMERGENCY LIGHTS HARNESS AND FOUND HARNESS DAMAGED INSIDE TRAY TABLE POCKET. HARNESS REPLACEMENT REQUIRED PARTS UPDATED PERFORMED GVI OF FIRST CLASS SEAT EMERGENCY LIGHTS HARNESS AND FOUND HARNESS DAMAGED IN TRAY TABLE POCKET (SEE IMG). HARNESS REQUIRES REPLACEMENT. REMOVED AND REPLACED EMERGENCY LIGHTING HARNESS AT SEAT 3AB IN REF TO COLLINS CMM 25-22-51-3671 PAGES 2005 AND 2013. OPS CHECKS GOOD AT THIS TIME.