As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR BEAM AT STA 1640 HAS VARIOUS SPOTS OF CORROSION. WORK ACCOMPLISHED ON BAM N/R 002799053 REMOVED DAMAGED SECTION OF FLOOR BEAM FABRICATED NEW SECTION, AND REPAIR PARTS TREATED PRIMED AND INSTALLED REF SRM 53-00-51-2R-8 AND ECRA 5360-02013 .