What was found
MID WET AREA AFTER FURTHER EVALUATION ON SEAT TRACK BETWEEN STA 500C AND 500E LBL 45 FOUND TO BE OUT LIMITS, REQUIRE REPAIR. REPAIRED AND RESTORED MID WET AREA ON SEAT TRACK BTW STA 500C-ST A500E LBL45 IAW SRM 53-00-52-2R-4,SRM 51-40-05-0G-0,SRM 51-40-08-0G-0, SRM 51-400-0G-0 SOPM 20-41-04, SOPM20-43-03,AMM20-50 -11-910-201,AMM 20-60-07-913-207.