What was found
FOUND 3 AREAS OF CORROSION IN STRINGER CHANNEL AT APPROX STA 811, STA 815, AND STA 832, STR 25L. REMOVED DAMAGE AT STA 811 -825 AT STR 25L HFEC REQUIRED AT CUT EDGE OF STR 25L AND APROX STA 811 REF SRM 53-00-03-2R-1 STEP 4 (C) PERFORMED HFEC AT CUT EDGE OF STR 25L AND APROX STA 811 REF SRM 53-00-03-2R-1 STEP 4 (C). NO DEFECTS NOTED IAW SRM 53-00-03-2R-1 TABLE 204. TRIMMED AND FABRICATED STRINGER REPAIR SECTION IAW SRM 53-00-03-2R-1 STEP 4D