What was found
MAIN CABIN FLOORBEAM UPPER TEE ANGLE HAS CORROSION AT BS 380 RBL 0. REMOVED CORROSION IAW IAW SRM 53-30-51. FOUND TO BE OUT OF LIMITS IAW 53-36-51, ORIG .125, MAT LOSS .038, REM .087 FABRICATED A STRAP AND FILLERS IAW REO-G25602 AND REO-25602 FIGURE 2. ALODINED & PRIMED IAW SRM 51-20-01-0G-. STRAP, & FILLERS INSTALLED IAW SRM 51-40-08. INSTALLED THE STRAP & FILLERS IAW REO-G25602 AND G25602 FIG 2 AND SRM 51-40-02. APPLIED CIC TO REPAIR AREA IAW SRM 51-20-01 AND EC/RA NO. 5300-07631.