What was found
HYD PUMP LOW PRESSURE SYS B ENG 2. HYD PUMP SWITCH IS OFF. RAN ENG NR 2. HYD PUMP LOW PRESSURE LIGHT ON SYS B ENG 2 & NO PRESSURE IND. R & R ENG 2 EDP IAW AMM 29-11-11. ENG TEST IAW AMM 71-00-00. OPS CHECK FAILED. ENG 2 LOW PRESSURE LIGHT REMAINS ON, & SYS B HYD ENG PRESSURE IND DID NOT RISE TO 2800 PSI OR HIGHER. ON INSP FOUND BULKHEAD PRESSURE FITTING AT PYLON BROKEN & PRESSURE HOSE PARTIALLY DISCONNECTED. R & R NR 2 ENG STRUT PRESSURE DISCONNECT FITTING IAW FIM 29-30 TASK 813. PAR F STEP 5. ALSO REPLACED EDP PRESSURE QUICK DISCONNECT HOSE. CHECKED CASE DRAIN FILTER IAW AMM 29-11-51-000-801. FILLED B SYS HYD IAW AMM 29-00-00-900-801. RAN ENG FOR EDP PRESSURE CONFIRM. OPS CHKD GOOD. EDP PRODUCES 3000 PSI MIN. IAW AMM 20-11-00-860-804.