What was found
MAIN CABIN FWD WET AREA INTERCOSTAL UPPER ANGLE CRACKED AT LBL 10" BETWEEN STA 380-400. INSTALLED NEW MAIN CABIN FWD WET AREA INTERCOSTAL UPPER ANGLE AT LBL 10" BETWEEN BS 380-400 IAW SRM 51-40-02-0G-0 & DWG 143A5400,
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FWD WET AREA INTERCOSTAL UPPER ANGLE CRACKED AT LBL 10" BETWEEN STA 380-400. INSTALLED NEW MAIN CABIN FWD WET AREA INTERCOSTAL UPPER ANGLE AT LBL 10" BETWEEN BS 380-400 IAW SRM 51-40-02-0G-0 & DWG 143A5400,